Permanent Connection
In the case of a permanent connection, it is
necessary that you install a double pole switch
between the hob and the electricity supply
(mains), with a minimum gap of 3 mm.
between the switch contacts and of a type
suitable for the required load in compliance
with the current electric regulations.
The switch must not break the yellow and
green earth cable at any point.
Ensure that the hob supply cord
does not come into contact with
surfaces with temperatures higher
than 50 deg. C.
FO 0390
Electrical connections
Any electrical work required to install
this hob should be carried out by a
qualified electrician or competent
person, in accordance with the current
regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This hob is designed to be connected to a
230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated
on the hob rating plate. The rating plate is
located on the bottom of the hob. A copy is
attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply
cord without plug. A proper plug, provided with
a 3amp ASTA approved (BS 1362) fuse must
be fitted to the cord.
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
1. Connect the green and yellow (earth)
wire to the terminal in the plug which is
marked with the letter 'E' or the earth
symbol or coloured green and yellow.
The earth wire should be about 2 cm
longer than the neutral and live wires.
2. Connect the blue (neutral) wire to the
terminal in the plug which is marked with
the letter 'N' or coloured black.
3. Connect the brown (live) wire to the
terminal in the plug which is marked with
the letter 'L' or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp
must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket
is a serious safety (shock) hazard. Ensure
that the cut off plug is disposed of safely.
Min. size
Cable/flex Cable / flex type Fuse
0.75 mm
2
H05 V2V2-F (T90) 3 A
Supply cable replacement
The cable used to connect the hob to the
electrical supply must comply to the
specifications given below.