Maintenance—Every 500 Hours
TX,80,JC1111 –19–18MAR96–2/2
T100705 –UN–22MAR96
644G Shown
2. Turn filter (A) counterclockwise to remove.
3. Clean mounting surface. Apply thin film of oil to gasket
of new filter.
4. Install new filter. Tighten filter 3/4—1 full turn after
seal contacts mounting base.
5. Fully loosen filter element. Repeat step 4.
6. Start engine. Check for leaks around the filter base.
Tighten filter only enough to stop leaks.
7. Stop engine. Check oil level.
TX,80,JC1112 –19–18MAR96–1/2
REPLACE HYDRAULIC RESERVOIR
BREATHER FILTER
Hydraulic reservoir breather filter is located on back side
of reservoir under the hood.